Taipei Headquarters

Data Center eASPNet

Enclosed Cabinet / VIP Independent Cabinet

Cabinet height: the full cabinet is 58 Units (Each unit is about 4.5 cm), Width: 60 cm (23.62 inch), Depth: 100 cm (39.37 inch), each cabinet is provided with an independent door lock and division boards are provided for use. The ventilation and convection in the cabinet are well designed. The bottom and top of the cabinet are equipped with anti-vibration mounts to prevent the cabinet from moving.

VIP independent cabinets are situated in an independent block, have independent access control and customized cabinet services, and monitoring systems are provided to ensure the security of the cabinet.

Power System

Generator System with Ample Backup

In order to maintain the safe operation of the system and prevent blackouts caused by external factors, the Internet data center is equipped with four dedicated emergency diesel generators for emergency dispatch, with a total capacity of 6000 kW. The generator system adopts the N+1 backup design and comes with the water cooling facilities and the emergency water source as the necessary facilities for maintaining the system during blackouts and when the water is off.

During blackouts, the first line of defense is an immediate power supply by the uninterruptible power system. The diesel generators will automatically start operation within 30 seconds, ensuring that any work in progress is not interrupted. All diesel generators are equipped with exhaust systems. The exhaust gas is guided to the top floor directly and released through a 16 inch ventilation pipe. In addition to reducing emission noise, there is a soot filter system, which fully addresses any environmental concerns.

As for oil supply, the company sets up a small oil tank in B1 with a capacity of 3,500 gallons. In addition, it has a large oil tank in B3 with a capacity of 9,000 gallons, which totals to a capacity of 12,500 gallons. It can supply the data center with electricity for 37 hours. In addition to the oil supply, the company has signed a contract with CNPC, requiring them to replenish the oil supply within 4 hours of receiving a phone call.

Uninterrupted Power System

The Internet data center is equipped with dual-looped, 2N backed up and automatic rectifier filter uninterrupted power system (AVR/on Line UPS). The uninterruptible power system uses professional batteries which do not need water replenishments and are maintenance-free and uses a low voltage/ High current design to provides quality uninterrupted supply of power. The uninterrupted power supply is capable of supplying power temporarily for 30 minutes. The power source in the data center all passes through the uninterrupted power system. In addition to providing power during blackouts, it also provides a highly reliable power source with stable voltage and current to prevent the equipment from being damaged due to powers supply problems such as surges.

 

Air Conditioning System/Raised Floor

The air-conditioning system in the Internet data center is a box-shaped computerized air-conditioning system blowing downwards with constant temperature and humidity. The air-conditioning system has a low failure rate and high efficiency. The dual-system design is used for two-stage power control to ensure extremely precise control of constant temperature and humidity. In order to meet the requirement of the system’s operating environment, the temperature of the air conditioning system is set at 24±2 degrees and the humidity is within the reasonable range of 40%~60%. In addition, to providing air-conditioning for the data center, the air conditioning system has N+1 backup design mechanisms. If the air conditioner fails, the other set can be provided backup to avoid affecting the operation of the system due to air conditioner failures, increasing the reliability of the system.

The raised floor is set up based on the guidelines for the specification of internet data center. The distance between the raised floor and the floor is 50 cm, and the raised floor can support a weight of more than 500 kg (inclusive) per square meter. The material of the raised floor is made of reinforced aluminum alloy and diagonal supports are added at each pivot to enhance seismic resistance.

Fire System

Environment Monitoring System

External Bandwidth

Security Mechanism

Security eASPNet
Security eASPNet
Security eASPNet

Network Operation Center

Award Certification

▪ TruSecure security certification

▪ Tier 3 grading machine room certification

▪ ISO 27001/27011 information security verification

▪ ISO 27017/27018 security for cloud services standard

▪TruSecure security certification

▪Tier 3 grading machine room
    certification

▪ISO 27001/27011 information
    security verification

▪ISO 27017/27018 security
    for cloud services standard

IDC Locations