Kaohsiung

Enclosed Cabinet

The full cabinet is 52 Units (Each unit is about 4.5 cm), Width: 60 cm (23.62 inch), Depth: 100 cm (39.37 inch), each cabinet is provided with an independent door lock and division boards are provided for use. The ventilation and convection in the cabinet are well designed. The bottom and top of the cabinet are equipped with anti-vibration mounts to prevent the cabinet from moving.

Uninterrupted Power System

The Internet data center is equipped with dual-looped, 2N+1 backed up and automatic rectifier filter uninterrupted power system (AVR/on Line UPS). The uninterruptible power system uses professional batteries which do not need water replenishments and are maintenance-free and uses a low voltage/ High current design to provides quality uninterrupted supply of power. The uninterrupted power supply is capable of supplying power temporarily for 20 minutes. The power source in the data center all passes through the uninterrupted power system. In addition to providing power during blackouts, it also provides a highly reliable power source with stable voltage and current to prevent the equipment from being damaged due to powers supply problems such as surges.

Air Conditioning System

The air-conditioning system in the Internet data center is a box-shaped computerized  air-conditioning system blowing downwards with constant temperature and humidity. The air-conditioning system has a low failure rate and high efficiency. The dual-system design is used for two-stage power control to ensure extremely precise control of constant temperature and humidity. In order to meet the requirement of the system’s operating environment, the temperature of the air conditioning system is set at 21±2 degrees and the humidity is within the reasonable range of 40%~60%. In addition, providing air-conditioning for the data center, the air conditioning system has N+1 backup design mechanisms. If the air conditioner fails, the other set can be provide backup to avoid affecting the operation of the system due to air conditioner failures, increasing the reliability of the system.

Network Operation Center

The Network Operation Center (NOC) is the core of the Internet Data Center. It is mainly responsible for monitoring and managing the status of various equipment of the data center connected to the network. The Network Operation Center is monitored by professionally trained personnel and engineers 24/7 on rotation.Operating and maintenance personnel use network management and environment monitoring tools to assist surveillance in the hope of discovering the problem early. When problems occur, the data center monitoring personnel can immediately grasp the problem. The problem is promptly forwarded, and certified professional engineers solve the problem for the customers. All the problems that have occurred are registered in the system of the customer center for future reference, with the goal of achieving the normal operation of the systems.

Fire System

Environment Monitoring System

Security Mechanism

Award Certification

▪ CSA STAR cloud security certification

▪ Tier 3 grading machine room certification

▪ ISO 27001/27011 information security verification

▪ Type II telecommunications and Special Type II telecommunications license