The DCT has a 5-story ceiling design, with a high load-bearing floor and an area of more than 2,000 square meters. The exterior walls are resistant to electromagnetic interference (EMI Protection). It can be divided into 3 areas: Modular Data Center (MDC), Containerized Data Center (CDC), and precision air conditioning in the computer room.
The earthquake resistance of buildings passed the test of an earthquake of 7 magnitude on the Richter Scale resistance to ensure that buildings won’t be easily affected by general earthquakes.
200 years of flood control frequency design, completely avoid water infiltration into the basement.
▪ Domestic: Deployed along the Taiwan Railways
▪ Overseas: Covers the densest submarine cable in Asia, and the shortest
distance from Taiwan to Hong Kong. Round-Trip Time to Hong Kong is
<14 milliseconds and to Taipei < 3 milliseconds
The power capacity of the entire IDC cabinet is 2,000kW, which is the only professional Cloud Internet Data Center in Taiwan that can provide a single cabinet of 20kW high-density power.
200 years of flood control frequency design, completely avoid water infiltration into the basement.
▪ Domestic
Deployed along the Taiwan Railways
▪ Overseas
Covers the densest submarine cable in Asia and the shortest
distance from Taiwan to Hong Kong. Round-Trip Time to Hong Kong is <14 milliseconds and to Taipei < 3 milliseconds
The power capacity of the entire IDC cabinet is 2,000kW, which is the only professional Cloud Internet Data Center in Taiwan that can provide a single cabinet of 20kW high-density power.
The full cabinet is 52 Units (Each unit is about 4.5 cm), Width: 60 cm (23.62 inch), Depth: 100 cm (39.37 inch), each cabinet is provided with an independent door lock and division boards are provided for use. The ventilation and convection in the cabinet are well designed. The bottom and top of the cabinet are equipped with anti-vibration mounts to prevent the cabinet from moving.
The Internet data center is equipped with dual-looped, 2N+1 backed up and automatic rectifier filter uninterrupted power system (AVR/on Line UPS). The uninterruptible power system uses professional batteries which do not need water replenishments and are maintenance-free and uses a low voltage/ High current design to provides quality uninterrupted supply of power. The uninterrupted power supply is capable of supplying power temporarily for 20 minutes. The power source in the data center all passes through the uninterrupted power system. In addition to providing power during blackouts, it also provides a highly reliable power source with stable voltage and current to prevent the equipment from being damaged due to powers supply problems such as surges.
The air-conditioning system in the Internet data center is a box-shaped computerized air-conditioning system blowing downwards with constant temperature and humidity. The air-conditioning system has a low failure rate and high efficiency. The dual-system design is used for two-stage power control to ensure extremely precise control of constant temperature and humidity. In order to meet the requirement of the system’s operating environment, the temperature of the air conditioning system is set at 21±2 degrees and the humidity is within the reasonable range of 40%~60%. In addition, providing air-conditioning for the data center, the air conditioning system has N+1 backup design mechanisms. If the air conditioner fails, the other set can be provide backup to avoid affecting the operation of the system due to air conditioner failures, increasing the reliability of the system.
The Network Operation Center (NOC) is the core of the Internet Data Center. It is mainly responsible for monitoring and managing the status of various equipment of the data center connected to the network. The Network Operation Center is monitored by professionally trained personnel and engineers 24/7 on rotation.Operating and maintenance personnel use network management and environment monitoring tools to assist surveillance in the hope of discovering the problem early. When problems occur, the data center monitoring personnel can immediately grasp the problem. The problem is promptly forwarded, and certified professional engineers solve the problem for the customers. All the problems that have occurred are registered in the system of the customer center for future reference, with the goal of achieving the normal operation of the systems.
The FM200 fire extinguishing system is used inside the data center. Because the data center equipment can not use the traditional fire extinguishing equipment of sprinkler or powder fire extinguisher, thus the latest technology FM200 fire extinguishing system is used. Its composition is heptafluoropropane, replacing the previous HALON system, The gas sprayed by the FM200 is an environmentally friendly product, it will not destroy the ozone layer, it is harmless to the human body and it will not have any impact on machinery and equipment. Fire extinguishing is applied within 30 seconds after the detection of a warning signal, it can quickly and effectively extinguish the fire source and prevent the disaster from spreading.
The VESDA multi-function early detection smoke alarm system is the most advanced system. The system consists of a smoke sensor tube and a laser sensor. The smoke sensor tube has holes for every 2 meters that covers an area of 8 cubic meters. The sensitivity of the laser sensor is 0.005 to 20% obs/m (Obscuration/meter), spread across each block on every floor to detect the chemical composition in the air. Once an abnormality is detected, the condition is transmitted to the Operation Center and issues a warning.
Temperature and humidity management of the data center.
Warning signal of FM-200 fire extinguishing system, alarm signal of the VESDA early detection smoke alarm system and fire alarm signal of the building.
Contains statistical information on overall electricity usage.
A liquid leakage detection system is installed in the data center to detect liquid leakage points and transmit information to the environment monitoring system.
When the Internet data center is invaded, an intrusion alarm is activated, and the intrusion point is recorded and processed immediately by the personnel of the data center.
▪ Security Guard Management
Security guards are in charge of security of the building 24/7. All non-staff personnel to the data center are checked and registered, and personnel in and out of the building are strictly filtered to avoid intrusion. The security guards will conduct regular patrols in the building to ensure the security of the data center. At the same time, the security systems will be connected with the security company. When problems occur, they will be rushed to the site for support at the earliest hour which enhances the security of the data center.
▪ Personnel Access Management
For visiting VIPs, they need to apply and register in advance, and staff of the data center will be sent to accompany the visiting guest to tour the data center. The guests who come to the data center to operate machinery should follow the management rules of the data center. The authorized personnel must show the authorization letter and cooperate with identity check procedures before entering the data center for maintenance work.
The card key system is installed at the entrances and exits of the data center and the elevator. The system controls the coming and going of the personnel through card keys. The approval of the application for the card key must be done by the security team to manage the personnel with access to the data center to ensure the security of the center. Data of personnel entering and leaving the data center will be stored in the computer responsible for access control for future reference.
Fixed camera and 360 degrees rotary camera are installed in each block of the internet data center, and provide surveillance for all areas of the facility, the monitoring system uses infrared technology recording system, when someone enters, the monitoring system will automatically switch to video of that location, monitoring all corners without blind spots, and the monitoring system can transmit over long distances through the internet, therefore, the images can be transmitted to the client. The surveillance video tapes recorded by the surveillance systems in accordance with the security management regulations, and stored in the cloud. When an intrusion occurs, surveillance tapes can be provided to assist the investigation.
▪ CSA STAR cloud security certification
▪ Tier 3 grading machine room certification
▪ ISO 27001/27011 information security verification
▪ Type II telecommunications and Special Type II telecommunications license
eASPNet Taiwan Inc. 4F., No. 101, Ruihu St., Neihu District, Taipei 114, Taiwan
Copyright © 2025 eASPNet Inc. All Rights Reserved.
eASPNet Taiwan Inc.
4F., No. 101, Ruihu St., Neihu District, Taipei 114, Taiwan
Copyright © 2025 eASPNet Inc. All Rights Reserved.